LTE 120F 80W/120 Dual Output Switching Power Supply
Input/ Output Specifications:
- VOLTAGE: 90-264 VAC, Universal
- FREQUENCY: 47-63
- CURRENT: 1.6 ARMS. MAX. @115VAC 122W LOAD, 0.8 ARMS. MAX. @230VAC 122W LOAD
- INRUSH SURGE: < 40 Ap-pl. @115Vac (Cold Start at 25 Degree) , < 70 Ap-pl. @230Vac (Cold Start at 25 Degree)
- OUTPUT WATTAGE: @ Convection Rating:80 Watts MAX, @ With 15CFM Forced Air Rating :122 Watts MAX
- OVERSHOOT/UNDERSHOOT OUTPUT RANGE: @ Turn-on / Turn-off---- < 5%
| Note: |
1. |
PEAK CURRENT LASTING < 30SECS WITH A MAXIMUM 10% DUTY CYCLE |
| 2. |
CROSS/LOAD REGULATION IS TESTED AT 10% TO 100% OF RATED LOAD AND OTHER OUTPUTS ARE SET AT 50% OF RATED LOAD. |
| 3. |
PEAK-TO-PEAK FOR 80W (CONVECTION RATING) @90VAC MIN, 122W (WITH 15CFM FORCED ARI) @ 100VAC MIN, MEASUREMENTS WITH A 20MHZ BANDWIDTH AND TERMINATED WITH A 10UF ELECTROLYTIC CAP. IN PARALLEL WITH A 0.1UF CERAMIC CAP. |
Environmental:
- OPERATING TEMPERATURE: 0°C TO 40°C Ambient
- STORAGE TEMPERATURE: -40°C TO 85°C
- HUMIDITY: @ Non-Condensing form 5% TO 95%
- VIBRATION: Random Operating, 2.4 Grms/Max. 3 axes, 50~500Hz 10 minutes/axis
- SHOCK: Operating, Half Sine, 3 Axes, 10mS, 6 shocks total 20 Gpk/Max
General Specifications:
- EFFICIENCY : >78% @115 Vac with full Load, >80% @ 230Vac With Full Load
- TURN-ON TIME: < 2 Sec @ 115Vac With Full Load
- HOLD-UP TIME: > 10mSec @ 115Vac With convection Rating
- MTBF DEMOSTRATED: > 100,000 Hours @ 25Degree With full Load, MIL-HDBK-217F
Electromagnetic Compatibility Specifications:
- EMI CONDUCTED/RADIATED: FCC PART 15 & CISPR22 & EN55022 CLASS
- BDESIGNED TO MEET EN61000 -3-2, -3-3, -4-2, -4-4, -4-5, -4-6, -4-11
Connector Type & Pin Assignments

Mechanical Drawing (5" x 3" x 1.5")

|